Product Details:

  • Material Other
  • Condition New
  • Operating Type Manual
  • Power Source Electric
  • Color White
  • Click to View more
X

Ryujin Plus Balloon Catheter Price And Quantity

  • 50 Piece
  • 4600 INR/Piece

Ryujin Plus Balloon Catheter Product Specifications

  • White
  • New
  • Other
  • Manual
  • Electric

Ryujin Plus Balloon Catheter Trade Information

  • 10000 Piece Per Week
  • 4 Days

Product Description

Ryujin Plus Balloon Catheter is used as part of asymptomatic and symptomatic peripheral artery disease treatment procedure. This balloon catheter has been specially developed to open blocked arteries in order to restore circulation of blood through legs and feet. Offered catheter is inserted through a precisely shaped small incision done in the leg. Its insertion causes minimal discomfort to patient. Kink proof design of its balloon simplifies insertion method of this catheter. Ryujin Plus Balloon Catheter can endure high inflation pressure at specific level in order to promote high flow rate of blood. A safety channel has been incorporated into its design to prevent its over inflation.


Product details

Average Burst Pressure

14 atm

Length

145 cm

Manufactured By

Terumo

Min GC

0.050 Inch(1.27mm)

Nominal Pressure

6 atm

Precautions

Do Not Use Open Or Damaged Packages And Use Prior To The Use By Date

Brand

Ryujin Plus

Packaging Type

Box

Material

Silicone

Size

Medium

Frequently Asked Questions

 

 

Q: Are there any dangers or issues with using a tiger catheter?


A: Using a tiger catheter has possible dangers and problems, much like any medical procedure involving catheterization. Infection at the site of insertion, haemorrhage, vascular damage, allergic reactions to contrast agents, embolism, and blood clots are a few examples of these. It is critical for patients to promptly report any unexpected symptoms or consequences and for medical providers to use proper insertion practises. 

Q: What is the operation of the Ryujin Plus balloon catheter?


A: The tip of the Ryujin Plus Balloon Catheter is an inflatable balloon. The radial or femoral artery is the most common blood channel through which the catheter is put. Using imaging methods, the catheter is then guided to the coronary arteries. The balloon is then inflated at the site of the blocked or constricted artery after being properly positioned. By compressing the plaque against the artery walls, the balloon's inflation widens the conduit and enhances blood flow.

Q: What distinguishing qualities does the Ryujin Plus Balloon Catheter have?


A: Several important elements that improve the performance and safety of the Ryujin Plus Balloon Catheter were incorporated into its design. These features could include, among others:

  • Low profile: The catheter's small shape makes it easier to implant and move through blood vessels without difficulty.
  • High pressure resistance: During inflation, the balloon is designed to sustain high pressures without rupturing.
  • The catheter has the best flexibility possible, making it simple to manoeuvre it inside the vasculature.
  • Radiopaque markers: These markers make the catheter more visible under fluoroscopy, so the doctor can position it precisely.

Q: Are there several sizes of the Ryujin Plus Balloon Catheter?


A: To meet varying patient anatomy and target vasculature, the Ryujin Plus Balloon Catheter is offered in a range of diameters. The size of the catheter that is used is determined by the lesion's features and the doctor's evaluation.

Q: A drug-eluting balloon (DEB) is the Ryujin Plus Balloon Catheter, correct?


A: The Ryujin Plus Balloon Catheter is not intended to be a drug-eluting balloon, hence, the answer is no. It is a typical balloon catheter used for stenting and angioplasty. However, there are additional varieties of catheters that combine the advantages of a balloon catheter with the capacity for drug eluting.

Q: Is there a chance that using the Ryujin Plus Balloon Catheter could have dangers or complications?


A: The Ryujin Plus Balloon Catheter has possible risks and problems, just like any other medical procedure. These may consist of:

  • allergic responses to the contrast chemicals or catheter materials.
  • vessel injury, such as perforation or dissection.
  • spasms of blood vessels.
  • Embolisation is the process by which minute particles or trash move to different areas of the body.
  • Restenosis is the gradual re-narrowing of the artery that has been treated.
  • The catheter insertion site is bleeding or infected.